National Cable Specialist

Teck Cable CU - 600 V | CSA Teck90 | Multi-Conductor

$5.49 CAD $5.49 CAD

Description

Teck Cable, Armored 600 V, CSA TECK90, Multi-Conductor, 10 or 6 AWG (depending on variant sele, Stranded Bare Copper, XLPE/PVC/AIA/PVC.

TECK90 is an interlocked armored cable for use in petro-chemical, pulp and paper, and other industrial application environments. TECK90 can be used in open and concealed wiring, direct burial, and in hazardous locations.

The insulated conductors are made with cross-linked polyethylene and twisted with an uninsulated ground wire. The twisted core is covered with a PVC jacket, then covered with either interlocked aluminum or galvanized steel, and covered with a PVC jacket over the armor.

 

Product Construction

Conductor:

  • 10 or 6 AWG (depending on variant selected)  bare copper Class B compressed concentric round to ASTM B8

Insulation:

  • Cross-linked Polyethylene (XLPE), Type RW90
  • Color-coded: 1 to 4 conductors— black, white, red and blue; over 4 conductors—per ICEA Method 4, individual conductors colored black with conductor number surface printed in contrasting ink

Ground (Bonding) Conductor:

  • The conductor consists of one uninsulated stranded bare copper conductor
  • Color-coded per ICEA Method 4; individual conductors colored black with conductor number surface printed in contrasting ink

Inner Jacket:

  • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

Armor:

  • Aluminum Interlocked Armor (AIA)

Overall Jacket:

  • Lead-free, ACID-FLAME-CHECK ✓✓® flameretardant,
  • moisture- and sunlight-resistant
  • Polyvinyl Chloride (PVC), black

Print:

  • GENERAL CABLE® ACID-FLAME-CHECK ✓✓®
  • AG14 FT1 FT4 HL TECK90 XLPE (-40˚C)#/C
  • SIZE (10 AWG) 600 V DIR BUR SUN RES CSA
  • MONTH-YEAR SEQUENTIAL LENGTH MARK

Options:

  • Galvanized Steel Interlocked Armor (GSIA)


Applications

  • For exposed and concealed wiring in dry, damp
  • or wet locations
  • For use in ventilated, non-ventilated and ladder type
  • cable trays in dry, damp or wet locations
  • For direct earth burial (with protection as required
  • by inspection authority)
  • For wiring in all hazardous locations when used
  • with certified HL cable glands

 

Features

  • Rated at 90˚C wet or dry
  • Excellent crush, oil and chemical resistance
  • Provides long service life
  • Meets cold bend and impact tests at -40˚C

 

Compliances

Industry Compliances:

  • CSA Standard C22.2 No. 131 and No. 174

Flame Test Compliances:

  • CSA FT1 and FT4
  • IEEE 383 (70,000 BTU/hr)
  • UL 1581 (70,000 BTU/hr)
  • IEEE 1202 (70,000 BTU/hr) CSA FT4
  • ICEA T-30-520 (70,000 BTU/hr)

Other Compliances:

  • Hazardous Location Rating: HL
  • EPA 40 CFR, Part 261 for leachable lead content per TCLP method
  • OSHA Acceptable
  • RoHS Compliant


Specifications

10-2C10-4C
ArmouredYes
AWG Size10
Voltage600V
No of Conductors24
Insulation MaterialCross-linked Polyethylene (XLPE)
CSAYes
Approximate Diameter Insulation (in.)0.18
0.18
Approximate Diameter Armour (in.)0.670.74
Approximate Diameter Outer Cable (in.)0.750.83
Armour MaterialAluminum Interlocked Armour (AIA)
ColorBlack
Conductor MaterialStranded bare copper
Steel Content LBS/1000 FT411565
AL Content LBS/1000 FT275
413
Flame Test RatingYes
Jacket MaterialPolyvinyl Chloride (PVC)
OptionsGalvanized Steel Interlocked Armour (GSIA). Other coloured outer jacket and constructions available upon request


Download the spec sheet